Wall sign rules in Garland
Allowed, with conditions. 37 confirmed rules: permit required, maximum area, minimum clearance, number allowed, minimum spacing, illumination, electronic message limits, submit with the application, other limit.
Example: Maximum area, Downtown (DT)30 sq ft“Wall Sign Not to exceed - Max area: 30 Min 10 ft Max of 1 per height of wall sq ft separation occupancy, per”Table 7-7 · View source · last checked Nov 13, 2026 - Highway frontage. Along IH-635, IH-30 and SH 190, larger wall signs are allowed, and electronic message signs have extra limits.
All wall sign figures for an addressChannel letters rules in Garland
Allowed, with conditions. 36 confirmed rules: permit required, maximum area, minimum clearance, number allowed, minimum spacing, illumination, electronic message limits, submit with the application, other limit.
Example: Maximum area, Downtown (DT)30 sq ft“Wall Sign Not to exceed - Max area: 30 Min 10 ft Max of 1 per height of wall sq ft separation occupancy, per”Table 7-7 · View source · last checked Nov 13, 2026 - Highway frontage. Along IH-635, IH-30 and SH 190, larger wall signs are allowed, and electronic message signs have extra limits.
All channel letters figures for an addressMonument sign rules in Garland
Allowed, with conditions. 29 confirmed rules: permit required, maximum area, maximum height, minimum clearance, number allowed, minimum setback, illumination, electronic message limits, submit with the application, other limit.
Example: Maximum area50 sq ft“Monument Sign 7 ft Max area: 50 sq ft 5 ft min setback”Table 4-10 · View source · last checked Nov 13, 2026 - Unified lot / multi-tenant complex signs. A multi-tenant complex sign is its own sign type with its own limits and needs a recorded unified lot sign agreement (§ 4.78(F)).
All monument sign figures for an addressPole or pylon sign rules in Garland
Allowed in some districts. 24 confirmed rules: permit required, maximum area, maximum height, minimum clearance, number allowed, minimum setback, minimum spacing, illumination, submit with the application, other limit.
Example: Maximum area150 sq ftApplies to: Pylon sign“Pylon Sign 22 ft Max area: 150 sq - 20 ft min setback”Table 4-10 · View source · last checked Nov 13, 2026 - Unified lot / multi-tenant complex signs. A multi-tenant complex sign is its own sign type with its own limits and needs a recorded unified lot sign agreement (§ 4.78(F)).
All pole or pylon sign figures for an addressBlade or projecting sign rules in Garland
Allowed, with conditions. 22 confirmed rules: permit required, maximum area, maximum height, minimum clearance, number allowed, illumination, submit with the application, other limit.
Example: Maximum area4 sq ftNote: Suspended beneath a ground-level canopy or awning, or attached to the façade on the ground level“ground level: Max ground level: Min area of 4 sq ft of 8 ft and max of Yes”Table 4-10 · View source · last checked Nov 13, 2026 All blade or projecting sign figures for an addressAwning or canopy sign rules in Garland
Allowed, with conditions. 37 confirmed rules: permit required, maximum area, minimum clearance, number allowed, maximum letter height, illumination, submit with the application, other limit.
Example: Maximum area25 sq ft (75% of the face of the canopy, max 25 sq ft (whichever is less))Applies to: Canopy sign“or to which it is - Min vertical attached, or 25 sq clearance of 8 ft ft, whichever is above any less”Table 4-10 · View source · last checked Nov 13, 2026 All awning or canopy sign figures for an addressWindow sign rules in Garland
Allowed, with conditions. 14 confirmed rules: permit required, maximum area, illumination, electronic message limits, other limit.
Example: Maximum area25%“- Area not to exceed 25% of total window No Sec. 4.78 surface area for each building facade that is visible from a public…”Table 4-10 · View source · last checked Nov 13, 2026 All window sign figures for an addressElectronic message sign rules in Garland
Allowed in some districts. 34 confirmed rules: permit required, maximum area, minimum clearance, number allowed, illumination, electronic message limits, submit with the application, other limit.
Example: Maximum area, Downtown (DT)100 sq ft“Changeable Max area: 100 - Sign shall be Max of 1 per Message Sign, sq ft attached to a venue Electronic building”Table 7-7 · View source · last checked Nov 13, 2026 - Highway frontage. Along IH-635, IH-30 and SH 190, larger wall signs are allowed, and electronic message signs have extra limits.
All electronic message sign figures for an addressTemporary banner rules in Garland
Allowed, with conditions. 23 confirmed rules: permit required, maximum area, maximum height, number allowed, minimum setback, submit with the application, other limit.
Example: Maximum area2 sq ft per linear ft of width of the associated tenant façade, max 200 sq ft (all temporary signs combined)“- Max area of all Freestanding: 15 ft Max in exceed height of temporary signs: 2 min setback nonresidential building sq ft per 1…”Table 4-10 · View source · last checked Nov 13, 2026 All temporary banner figures for an address64 more lines could not be confirmed by our automatic checks, so no figures are shown for them. A lookup lists them with the section to check.