Coverage · Seagoville, TX

Seagoville, Texas sign rules

286 confirmed rules from the City of Seagoville's sign code for 9 sign types, each quoted word for word with its code section and a link to the official source. Last checked Nov 14, 2026.

Check an exact address in Seagoville

Most limits depend on the zoning district. Enter the address to get every confirmed figure for that lot.

What the confirmed rules cover

Wall sign rules in Seagoville

Allowed, with conditions. 30 confirmed rules: permit required, maximum area, minimum clearance, illumination, permit fee, submit with the application, other limit.

Example: Maximum area20% (greater of 20% of the wall surface or 40 sq ft, capped at 250 sq ft)“Maximum size/area: Twenty (20) percent of wall surface or forty (40) square feet, whichever is larger.”§ 21.09.005(i)(2) · View source · last checked Nov 14, 2026
  • No sign taller than the zoning district allows. Signs may not exceed the maximum building height of the zoning district (§ 21.09.011(a)). District building heights are in the zoning ordinance, which is not shown here.
All wall sign figures for an address

Channel letters rules in Seagoville

Allowed, with conditions. 28 confirmed rules: permit required, maximum area, minimum clearance, illumination, permit fee, submit with the application, other limit.

Example: Maximum area20% (greater of 20% of the wall surface or 40 sq ft, capped at 250 sq ft)Applies to: As a wall sign“Maximum size/area: Twenty (20) percent of wall surface or forty (40) square feet, whichever is larger.”§ 21.09.005(i)(2) · View source · last checked Nov 14, 2026
  • No sign taller than the zoning district allows. Signs may not exceed the maximum building height of the zoning district (§ 21.09.011(a)). District building heights are in the zoning ordinance, which is not shown here.
All channel letters figures for an address

Monument sign rules in Seagoville

Allowed, with conditions. 49 confirmed rules: permit required, maximum area, maximum height, minimum clearance, number allowed, minimum setback, minimum spacing, illumination, electronic message limits, permit fee, submit with the application, other limit.

Example: Maximum area, Nonresidential125 sq ftApplies to: Non-residential uses“Maximum size/area: One hundred twenty-five (125) square feet.”§ 21.09.005(g)(1)(B) · View source · last checked Nov 14, 2026
  • No sign taller than the zoning district allows. Signs may not exceed the maximum building height of the zoning district (§ 21.09.011(a)). District building heights are in the zoning ordinance, which is not shown here.
  • Electronic message centers on monument signs. A monument sign's message center may only take up part of the sign and show time and temperature or fuel prices, while the electronic message sign definition allows a larger changeable share. Ask the city how they combine.
All monument sign figures for an address

Pole or pylon sign rules in Seagoville

Allowed in some districts. 41 confirmed rules: permit required, maximum area, maximum height, minimum clearance, number allowed, minimum setback, illumination, permit fee, submit with the application, other limit.

Example: Maximum area200 sq ftApplies to: Sign up to 50 ft tall“Maximum size/area: Two hundred (200) square feet for up to fifty feet (50') tall.”§ 21.09.005(h)(2) · View source · last checked Nov 14, 2026
  • Pole signs only near U.S. Highway 175. Pole/pylon signs are allowed only in nonresidential districts near the U.S. Highway 175 right-of-way line, and in nonresidential planned developments (§ 21.09.005(h)(3)).
  • No sign taller than the zoning district allows. Signs may not exceed the maximum building height of the zoning district (§ 21.09.011(a)). District building heights are in the zoning ordinance, which is not shown here.
All pole or pylon sign figures for an address

Blade or projecting sign rules in Seagoville

21 confirmed rules: permit required, minimum clearance, illumination, permit fee, submit with the application, other limit.

Example: Minimum clearance8 ftNote: Over a sidewalk or pedestrian travel surface“Projecting signs shall have a minimum clearance of eight (8) feet above any sidewalk/pedestrian travel surface, and fourteen (14) feet above any vehicular parking…”§ 21.09.012(b) · View source · last checked Nov 14, 2026
  • Projecting signs. The sign code sets clearances for projecting signs but lists no standards for them, and sign types not expressly permitted are prohibited. Ask the city before ordering a projecting sign.
All blade or projecting sign figures for an address

Awning or canopy sign rules in Seagoville

Allowed. 39 confirmed rules: permit required, maximum area, minimum clearance, number allowed, illumination, permit fee, submit with the application, other limit.

Example: Maximum area75%Applies to: Awning signs“Maximum size/area: Not to exceed seventy-five (75) percent of the length of the awning.”§ 21.09.005(a)(2) · View source · last checked Nov 14, 2026
All awning or canopy sign figures for an address

Window sign rules in Seagoville

Allowed. 18 confirmed rules: permit required, illumination, permit fee, submit with the application, other limit.

Example: Permit fee$25Applies to: Window sign larger than 20% of the window surface area (permit required); sign area up to 100 sq ft“Signs Up to 100 square feet $ 25.00 $ 25.00”Seagoville Master Fee Schedule FY 2026-2027 (fees effective 10/1/26), Master Fee Schedule FY 2026-2027, Building Inspection, Signs · View source · last checked Nov 14, 2026
All window sign figures for an address

Electronic message sign rules in Seagoville

Allowed. 31 confirmed rules: permit required, number allowed, illumination, electronic message limits, permit fee, submit with the application, other limit.

Example: Number allowed1“See standard for the type of sign it is part of (monument sign, pole/pylon sign, wall sign, etc.). (2) Maximum number: One (1) per…”§ 21.09.005(c)(2) · View source · last checked Nov 14, 2026
  • Electronic message centers on monument signs. A monument sign's message center may only take up part of the sign and show time and temperature or fuel prices, while the electronic message sign definition allows a larger changeable share. Ask the city how they combine.
All electronic message sign figures for an address

Temporary banner rules in Seagoville

Allowed in some districts. 29 confirmed rules: permit required, maximum area, maximum height, number allowed, permit fee, submit with the application, other limit.

Example: Maximum area60 sq ft“Maximum height: Six feet (6'). (2) Maximum size/area: Sixty (60) square feet.”§ 21.09.006(a)(2) · View source · last checked Nov 14, 2026
  • Banner fee. The fee schedule has no banner row; the fee shown is the portable sign fee, because the code defines a banner as a kind of portable sign. Confirm with the city.
All temporary banner figures for an address

44 more lines could not be confirmed by our automatic checks, so no figures are shown for them. A lookup lists them with the section to check.

Before you file in Seagoville

  • Planned developmentsIn a PD district, the sign standards in the planned development ordinance apply; only if it sets none does the sign ordinance apply (§ 21.09.009). Check the PD ordinance with the city.
  • Certificate of occupancy firstThe city does not issue a sign permit to a business without a valid certificate of occupancy or a complete building permit or certificate of occupancy application (§ 21.09.066(b)).

Official sources

Permits: The City of Seagoville sign permit office, 972-287-6833. Zoning districts: Seagoville zoning map.

Not legal advice. The city has the final say. Planned developments, master sign plans and special sign districts can override the general sign code. Check the linked section before you file.

Rules are extracted from official city documents by AI and checked automatically, not reviewed by a person. How the checks work

All covered Texas cities and towns

Seagoville, TX sign rules: wall, monument and pole signs · WhatSignFits